+1 587 578 5242Desk closed, leave a request
ENERGINNTechnology Solutions

Gas detection

Fixed gas detection for oil and gas sites: H2S and other toxic gases, combustible gas (LEL) and oxygen, with electrochemical, catalytic and infrared sensors.

Each line lists the gas and the sensor technology. Tell us the area classification, the gases and the control system it reports to, and the desk confirms the sensor cartridges and accessories.

Productpart numberGasSensor technologyModelOutputOriginmade inStockavailabilityPriceper unitBuyingmodeAction
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00495Carbon dioxide 0-2 %VolInfraredXCD mV transmitter + IR CO2 sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00499Oxygen 25.0 %Vol onlyElectrochemicalXCD O2 transmitter + O2 sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00492Flammable gases 20.0-100.0 %LEL (default CH4 0-100 %LEL; flammable 1-8 cal curves)Catalytic beadXCD mV transmitter + catalytic sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00494Methane 0-100 %VolInfraredXCD mV transmitter + IR methane %Vol sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00496Hydrogen sulfide 10.0-100.0 ppm (default 50 ppm)Electrochemical (Surecell)XCD EC transmitter + H2S sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00498Hydrogen 1,000 ppm onlyElectrochemicalXCD EC transmitter + H2 sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00497Carbon monoxide 100-1,000 ppm (default 300 ppm)Electrochemical (Surecell)XCD EC transmitter + CO sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Gas Detectors · Sensepoint XCDEN-GDT-00493Methane 20.0-100.0 %LELInfraredXCD mV transmitter + IR methane %LEL sensor4-20 mA (sink/source selectable) + Modbus; 2 programmable alarm relays + 1 fault relayCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00517Ammonia (NH3) Hi 200 to 1,000 ppm (default 1,000 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSA2SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00516Sulphur dioxide (SO2) Lo 5.0 to 20.0 ppm (default 15 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSS1SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00515Carbon monoxide (CO) 100 to 500 ppm (default 300 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSC1SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00518Nitrogen dioxide (NO2) 5.0 to 50.0 ppm (default 10 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSN1SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00520Hydrocarbons 20-100 %LEL (propane cal) / methane 20-100 %LEL or 1-5 %VolPoint infrared (XNX MPD IR HC / IR CH4)XNX with mV personality + MPD IR HC (IF1) / IR CH4 (IV1)4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00513Hydrogen sulphide (H2S) Lo 10.0 to 50.0 ppm (default 15 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSH1SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00514Hydrogen sulphide (H2S) Hi 50 to 500 ppm (default 100 ppm)Electrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSH2SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00512Oxygen (O2) 25.0 %Vol fixedElectrochemical (XNX EC sensor cartridge, hot-swappable, IS)XNX with EC personality + cartridge XNXXSO1SS4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00523Hydrocarbons (flammable), open path 5-40 mOpen-path infrared - Searchline ExcelXNX with IR personality + Searchline Excel4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00519Flammables 20-100 %LEL (methane cal)Catalytic bead (XNX MPD)XNX with mV personality + MPD catalytic (CB1)4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00521Carbon dioxide 1.00-5.00 %VolPoint infrared (XNX MPD IR CO2)XNX with mV personality + MPD IR CO2 (IC1)4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Honeywell Universal Gas Transmitters · XNXEN-GDT-00522Hydrocarbons (flammable), point IRPoint infrared - Searchpoint Optima PlusXNX with IR personality + Searchpoint Optima Plus4-20 mA (sink/source/isolated) + HART standard; optional relays, Modbus RTU or FOUNDATION Fieldbus (mutually exclusive)CanadaMade to orderOn requestquoted by the deskBy RFQAdd

Page 1 of 1 · 20 line items