+1 587 578 5242Desk closed, leave a request
ENERGINNTechnology Solutions

Level measurement

Level measurement for oil and gas production: non-contact radar for storage and process tanks, and guided wave radar for interface and level in separators and small chambers.

Each model lists its measuring principle, range and output. Send the tag list or the process conditions with your RFQ and the desk confirms the right configuration with the manufacturer.

Productpart numberMeasurementModelMeasuring rangeOutputOriginmade inStockavailabilityPriceper unitBuyingmodeAction
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00527Level and interface5302, rigid single lead 8 mm (4A)Probe length 0.4 to 3 m (1 ft 4 in to 9 ft 10 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00529Level and interface5302, segmented rigid single lead 13 mm (4S)Probe length 0.4 to 10 m (1 ft 4 in to 32 ft 9 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00525Level and interface5302, coaxial perforated probe (3B)Probe length 0.4 to 6 m (1 ft 4 in to 19 ft 8 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00524Liquid level5301, coaxial probe (3A)Probe length 0.4 to 6 m (1 ft 4 in to 19 ft 8 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00528Level and interface5302, rigid single lead 13 mm (4B)Probe length 0.4 to 6 m (1 ft 4 in to 19 ft 8 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00531Solids level5303, flexible single lead 4 mm with weight (5A) or chuck (5B)Probe length 1 to 35 m (3 ft 4 in to 115 ft)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00526Level and interface5302, large coaxial perforated probe (3C)Probe length 0.3 to 6 m (1 ft to 19 ft 8 in)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00530Level and interface5302, flexible single lead with weight (5A) or chuck (5B)Probe length 1 to 50 m (3 ft 4 in to 164 ft)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Guided Wave Radar Level Transmitters · 5300EN-LVL-00532Solids level5303, flexible single lead 6 mm with weight (6A) or chuck (6B)Probe length 1 to 50 m (3 ft 4 in to 164 ft)4-20 mA HART (H), FOUNDATION Fieldbus (F) or RS-485 Modbus (M)CanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00544Liquid level5408 (Profile A), standard accuracy ±0.08 in (2 mm)Up to 130 ft (40 m); 492 ft (150 m) with option ER4-20 mA HART or FOUNDATION FieldbusCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00546Solids level5408 (Profile A), standard accuracy ±0.08 in (2 mm)Up to 130 ft (40 m); 492 ft (150 m) with option ER; solids guideline 16-295 ft (5-90 m) by antenna4-20 mA HART or FOUNDATION FieldbusCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00549Solids level (functional safety)5408:SIS (Profile F), SIL 2 / SIL 3 capableUp to 130 ft (40 m)4-20 mA HARTCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00548Liquid level (functional safety)5408:SIS (Profile F), SIL 2 / SIL 3 capableUp to 130 ft (40 m) standard; 50 ft (15 m) ultra accuracy4-20 mA HARTCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00545Liquid level5408 (Profile A), ultra accuracy ±0.04 in (1 mm)Up to 50 ft (15 m)4-20 mA HART or FOUNDATION FieldbusCanadaMade to orderOn requestquoted by the deskBy RFQAdd
Rosemount Non-Contact Radar Level Transmitters · 5408EN-LVL-00547Liquid & solids level5408 (Profile A), standard accuracy ±0.08 in (2 mm)Up to 130 ft (40 m); 492 ft (150 m) with option ER4-20 mA HART or FOUNDATION FieldbusCanadaMade to orderOn requestquoted by the deskBy RFQAdd

Page 1 of 1 · 15 line items